DEGSON 2CDGVM-5.08-100AH PLUGGABLE TERMINAL BLOCK
Quantity
Item | Data | ||
APPROVAL | / | ||
Test standard | IEC61984 / UL1059 | ||
Pitch [mm] | 5.08 | ||
Poles | 2-22P | ||
IEC61984 Test data | IEC61984 | ||
Rated voltage [V] | 320 | ||
Rated current [A] | 12 | ||
Rated connection capacity (solid/stranded) [mm²] | / | ||
(Surge voltage category/pollution degree/material group) | III/2/I | ||
Rated impulse voltage [KV] | 4 | ||
Rated torque [N·m] | / | ||
UL1059Test data | UL1059 | ||
Use group | B | C | D |
Rated voltage [V] | 300 | / | / |
Rated current [A] | 15 | / | / |
Rated connection capacity (solid/stranded) [AWG] | / | ||
Rated torque [Lb. in] | / | ||
General data | / | ||
Screw | / | ||
Inflammability class UL94 | V-0 | ||
Ambient temperature [¡æ] | -40~+105 | ||
Relative humidity | 5%-95% | ||
Inspection standard | MIL-STD-105E II | ||
AQL | 0.65 | ||
Warranty | 12 months | ||
Material and plating | / | ||
Housing | PA66+GF | ||
Nut | Steel£¬Zn plated | ||
Nut | Copper alloy | ||
Contact | Copper alloy£¬Sn plated |