DEGSON 8EDGKC-7.5/7.62 PLUGGABLE TERMINAL BLOCK
Quantity
Item | Data | |||
|
||||
Test standard | IEC/EN61984£º2009 / UL1059 | |||
Pitch [mm] | 7.5 | |||
Poles | 2-12P | |||
EN61984 Test data | / | |||
Rated voltage [V] | 400 | |||
Rated current [A] | 20 | |||
Rated connection capacity (solid/stranded) [mm²] | 0.2-2.5 | |||
(Surge voltage category/pollution degree/material group) | III/3/I | |||
Rated impulse voltage [KV] | 4 | |||
Rated torque [N·m] | / | |||
UL1059Test data | UL File Number E228872 | |||
Use group | B | C | D | |
Rated voltage [V] | 300 | 300 | 300 | |
Rated current [A] | 15 | 15 | 10 | |
Rated connection capacity (solid/stranded) [AWG] | 22-14 | |||
Rated torque [Lb. in] | / | |||
General data | / | |||
Screw | / | |||
Inflammability class UL94 | V-0 | |||
Ambient temperature [¡æ] | -40~+105 | |||
Relative humidity | 5%-95% | |||
Inspection standard | MIL-STD-105E II | |||
AQL | 0.65 | |||
Warranty | 12 months | |||
Material and plating | / | |||
Housing | PA66 | |||
Contact | Copper alloy£¬Sn plated | |||
Recommended stripping length 9-10mm; | ||||
1.£©For solid wire: after stripping corresponds to the length of the wire , put the wire into the hole after using the accessory depress the cage spring . | ||||
2.£©For strand wire :after stripping corresponds to the length of the wire, can be directly connected or use of the corresponding standard insulated ferrule , then put the wire into the hole after using the accessory press the cage spring. |